3/25/2021 0 Comments Profinet Gsdml Files
Furthermore, the integrated IO Configurator of Robotstudio is under development and soon you should be able to import all you devices there too and create a valid configuration.Hi all I have faced a couple of troubles this week doing actually very common operation and I hope someone could give me an helping hand.What have i tried till now Lurking trough the internets tells that there are several possible ways for configuring my controller as PN-Master.
According to some application notes and manuals (such as 3HAC039906-001 Rev. Profinet Gsdml Files Software Such AsD ) to perform such configuration you need 3rd party software such as PROFINET-Configurator by KW-Software or PC WORX by Phoenix Contact ( which actually schould be the same thing, but it isnt). Since v6.05 of RobotWare it should be also possible to perform PN-Conffiguration even directly in RobotStudio. Ive tried out all of them: a) PROFINET-Configurator (by KW-Software) PRO: I can configure my devices with this tool and it works on controller. CONTRA: It only accepts GSML with verison I can only configure my 1st and 2nd device There isnt and will never be any newer version - Company acquired by Phoenix b) PC Worx v6.30.1914 (by Phoenix Contact) PRO: Only this tool was able to parce all GSDML files CONTRA: Controller doesnt accept IPPNIO.xml generated this way. I attached my PC WORX zipped Project as.ZWT if somebody could test it out. CONTRA: It only accepts GSML with verison v2.3. So I can only configure my 4th 5th 6th device The Problem How am I supposed to configure my whole PROFINET-system in this situation Workarounds a) Merge IPPNIOs (failed) I tried to insert sections of the IPPNIO generated by Robotstudio and PN-Configurator, which are working separately, into each other. Robotstudio claims a corrupt PROFINET-Configuration File and cannot automatically add described devices. I have no idea, which part of description could be wrong, if both parts are right forc each self. Such way needs on the one hand a lot of time and on the other hand - access to the Profinet-specification (which arent open for some reason). Unfortunately I am not a member of PBPN Commitee and cannot download it ( but probably someone of you guys can ). I use the Software Config from Phoenix Contact and it was part of PC Worx. Colud you please tell me a bit more Maybe you could post a your recent config Compared to Profinet configurator i cannot parametrize anything here. I figured out, that Config requires additional licence and I dont have one I would like to configure my system as following(due to demo-mode I cannot even save this config): Thanks in Advance. Also possible with demo version Then you can import these FDCMLs into Config. Hi, Can you please help me with this problem Im exactly trying to do the same thing as you. My setup is almost like yours: IRB 4600 with IRC5 and 888-2 Option RobotWare version 6.07.01.00 In my case the slave device is Beckhoff (cx8093) with. I used the IO configurator in RobotStudio to configure the slave device and that worked on the IRC5. I can see from RobotStudio that the Slave device is configured and running. My problem is when I set a digital output or input signal in RobotStudio and assigned it to the configured slave device, I get error number 71362 (IO signal mapped outside the IO device data area). Do you know if it is possible to change the Input and Output size data for the IO device from RobotStudio As you can see in the screenshot, the Output and input data area size for IO device is 0 bits currently. KW Software changed its name to Phoenix Contact Software quite some time ago so I am suspecting that you may be using a very old tool. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |